|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
65W Quad Output Switching Power Supply Features : Universal AC input / Full range RQ-65 series Protections:Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty .. SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE RQ-65B CH1 5V 6A Note.6 0.5 ~ 8A Note.6 62.5W RQ-65C CH2 12V 2A 0.2 ~ 3A CH3 -5V 0.5A 0 ~ 1A CH4 -12V 0.5A 0 ~ 1A CH1 5V 5A 0.5 ~ 8A 65W CH1: 4.75 ~ 5.5V 2.0% +10,-4% 0.5% 0.5% 1.5% 4.0% CH2 15V 2A 0.2 ~ 3A CH3 -5V 0.5A 0 ~ 1A CH4 -15V 0.5A 0 ~ 1A RQ-65D CH1 5V 4A 0.5 ~ 8A 68W CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% 0.5% 1.5% 3.0% CH2 12V 1.5A 0.2 ~ 3A CH3 24V 1A CH4 -12V 0.5A 0.1 ~ 1.5A 0 ~ 1A RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% +7,-5% Note.4 Note.5 5.0% 0.5% 1.0% 5.0% 0.5% 1.0% 5.0% 0.5% 1.0% 5.0% 0.5% 1.0% 8.0% 2.0% 5.0% 5.0% 0.5% 1.0% 0.5% 0.5% 1.5% 3.0% 500ms, 20ms/230VAC 60ms/230VAC 88 ~ 264VAC 47 ~ 63Hz 76% 1200ms, 30ms/115VAC at full load 14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 76% 78% 2A/115VAC 1.2A/230VAC COLD START 40A/230VAC <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH SAFETY & EMC (Note 7) I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF 245.5Khrs min. MIL-HDBK-217F (25 ) Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 129*98*38mm (L*W*H) 0.44Kg; 30pcs/13.2Kg/0.72CUFT OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:RQ-65-SPEC 2008-09-17 65W Quad Output Switching Power Supply Mechanical Specification 122.5 7 RQ-65 Case No. 903 series Unit:mm 1 8.25 2 4 5 6 7 8 7 2- M3 3 33 31 3.5 85.5 98 3 .5 4.5 73.5 129 6.5 120 18.5 9.5 Terminal Pin No. Assignment Pin No. 1 2 3 4 Assignment AC/L AC/N FG DC OUTPUT -V4 Pin No. 5 6 7 8 Assignment DC OUTPUT V3 DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 3.5 28.5 38 9 3-M 3 32 77 RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER Block Diagram 18 Derating Curve 3.5 I/P EMI FILTER FG +V4 fosc : 60KHz +V3 +V2 +V1 COM RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. O.L.P. CONTROL Output Derating VS Input Voltage Ta=25 100 80 60 LOAD (%) 40 20 -25 -25 0 0 10 20 30 40 50 60 70 (VERTICAL) LOAD (%) 88 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RQ-65-SPEC 2008-09-17 |
Price & Availability of RQ-65 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |